Wrist-Mountable Underwater Thickness Gauge
Overview
Kit Contents
Specifications
Display |
2.8” quarter VGA colour AMOLED (320 x 240 pixels)
Large clear thickness measurement (15 mm high numbers), viewable from all angles
A-Scan display with automatic X axis
Battery level, signal strength, probe type, velocity
Measurement mode and units indication
|
Battery |
Single 3.6V Li-ion 8.2 W battery
11 hours continuous measurement
Low battery warning ‘alert’ message
|
Measurement Modes |
Multiple-Echo (three back-wall echoes) using Single Crystal
(zero-degree) probes automatically ignores surface coatings and measures
only metal thickness
Echo-Echo (two back-wall echos) using Twin Crystal probes
Single-Echo (first back-wall echo) using Twin Crystal probes
|
Deep Coat | In Multiple-Echo mode, allows measurement to be made through thicker coatings of suitable materials of up to 20 mm thick |
Accuracy | ±0.1 mm (±0.004”) or 0.1% of thickness measurement, whichever is greatest, when calibrated in accordance with Cygnus Instruments calibration procedure |
Probe Cables |
Double outer jacket in tough PU. Coloured yellow for easy
locations underwater. Coiled for ease of use. Fischer S105 series
connectors.
|
Measurement Ranges |
Multiple-Echo (through coatings) with Single Crystal probes:
2.25 MHz = 3.0 to 250 mm
3.5 MHz = 2.0 to 150 mm
5.0 MHz = 1.0 to 50 mm
Echo-Echo with Twin Crystal probes:
5.0 MHz = 4.0 to 50 mm in steel
2.0 MHz = 6.0 to 50mm in steel
Single-Echo with Twin Crystal probes:
5.0 MHz = 2.0 to 100 mm in steel
2.0 MHz = 3.0 to 150 mm in steel
|
Measurement Resolution |
0.1 mm – Low resolution mode or measurement >99.95 mm
0.05 mm – High resolution mode and measurement <100.0 mm
0.01 mm – Single-Echo mode only and measurement <100.0 mm
|
Measurement Units | mm or inches |
Probe Zero | Fully automatic probe zeroing for all probes types |
V-Path Correction | Automatic V-Path correction for all Twin Crystal probes |
Velocity Range | 2000 to 9000 m/s in 1 m/s setps |
Pulser | Twin channel 70 V spike pulser |
Receiver / Amplifier |
10 MHz bandwidth, 120 dB range, automatic TCG
60 MHz measurement time-base
|
Data Logging |
One-handed automatic logging of stable measurements. Capacity for up to 5000 points including 640 point A-Scan data.
|
Data Output | RS-485 single pair, half duplex for surface connection |
Computer Software | CygLink v4 allows remote logging and viewing of A-Scan graphs. Survey and report generation to PDF file. Graphic analysis of data and statistical calculations. Designed for Windows 7 and Windows 8. |
Standards | Designed for EN 15317 |
Probes
Single Crystal probes: | 2.25 MHz 13 mm (standard) S2C |
2.25 MHz 19 mm S2D | |
3.5 MHz 13 mm S3C | |
5.0 MHz 6 mm S5C | |
Twin Crystal probes: | 2.0 MHz 13 mm x2 (for some plastics e.g. outfall pipes) T2C |
5.0 MHz 8 mm x2 (standard) T5B |
Downloads